Free shipping over $99

{"id":6550243704875,"title":"4ft 18W LED Linear Tube - Glass - Single\/Two End Bypass - Safety Thermal Fuses - Ballast Bypass - (UL Type B + DLC) *Buy By The Box Promo*","handle":"4ft-18w-led-linear-tube-glass-single-two-end-bypass-safety-thermal-fuses-ballast-bypass-ul-type-b-dlc","description":"\u003cdiv class=\"page\" title=\"Page 2\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003e*MUST BUY IN MULTIPLES OF 25PC TO GET THE EXCLUSIVE OFFER* \u003c\/span\u003e\u003c\/p\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cspan\u003eNOTE: You must bypass the ballast. \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eExisting ballast can not be wired\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for this tube to work. Follow rewiring instructions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe LED T8 Glass Tube operates as a Bypass Tube which means it will bypass the existing ballast. These Glass T8 Tubes are energy efficient and provide energy savings of 70% or more. The T8 Tube produces over 100 Lumens per Watt. Additionally, the T8 Tubes are Eco-Friendly LED lights which do not emit UV or IR Radiation. Also, this lights provide great lighting without the occasional Flickering you may encounter with other tube lighting. Furthermore, the T8 Glass Tubes are Mercury Free and provide 50,000 hours or more of working bulb light. Our Glass Tubes are UL\/DLC Listed and come with a 3 year warranty.\u003c\/p\u003e\n\u003cp\u003eThis product is listed under DesignLights Consortium® (DLC) which does not only provide eligibility for rebates from most utility providers, but also promotes high-quality and energy-efficient lighting products through vigorous testing protocols.\u003c\/p\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003cp\u003eSKU: \u003cspan\u003e (4000K Milky) 101-100105,  (5000K Milky) 101-100106\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e (4000K Transparent) 101-100107, (5000K Transparent) 101-100108\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eQualification: UL\/DLC Listed\u003c\/p\u003e\n\u003cp\u003ePower: 18W\u003c\/p\u003e\n\u003cp\u003eReplaces up to: 32W T8 FL\u003c\/p\u003e\n\u003cp\u003eColor: 4000K, 5000K\u003c\/p\u003e\n\u003cp\u003eCRI: \u0026gt; 80\u003c\/p\u003e\n\u003cp\u003eInput Voltage: AC100-277V\u003c\/p\u003e\n\u003cp\u003ePower Factor: ≥ 0.90\u003c\/p\u003e\n\u003cp\u003eLifespan: 50,000 hours\u003c\/p\u003e\n\u003cp\u003eLumens: 2300LM\u003c\/p\u003e\n\u003cp\u003eLumens Per Watt (LPW): 100LPW\u003c\/p\u003e\n\u003cp\u003eBeam Angle (°): \u0026gt;220°\u003c\/p\u003e\n\u003cp\u003eWarranty: 5 years\u003c\/p\u003e\n\u003cp\u003eBase Type: G13\u003c\/p\u003e\n\u003cp\u003eMaterials: Glass\u003c\/p\u003e\n\u003cp\u003eIP Rating: IP20\u003c\/p\u003e\n\u003cp\u003eTrim: Clear, Frosted\u003c\/p\u003e\n\u003cp\u003eWiring: Single End \/ Two End\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0931\/8152\/files\/tempGrid_large.jpg?v=1500904352\" alt=\"\" width=\"578\" height=\"273\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eOperation and Maintenance Tips\u003cbr\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eStore and use the lamps as same as standard fluorescent lamps\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLamps should be kept free from contamination\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e Switch off mains supply before installing\/removing lamp\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eGood condition of the lamp-holder contacts is important to ensure proper operation of lamp\u003cbr\u003e \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e Use in fully enclosed fixtures may affect life performance\u003cbr\u003e \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e Not for use in emergency lighting circuits\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"\"\u003e\u003cstrong\u003e*When wiring single ended tubes, please ensure you are using an unshunted socket\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--\n.tftable {font-size:12px;color:#333333;width:100%;border-width: 1px;border-color: #a9a9a9;border-collapse: collapse;} .tftable th {font-size:12px;background-color:#b8b8b8;border-width: 1px;padding: 8px;border-style: solid;border-color: #a9a9a9;text-align:left;} .tftable tr {background-color:#ffffff;} .tftable td {font-size:12px;border-width: 1px;padding: 8px;border-style: solid;border-color: #a9a9a9;}\n--\u003e\u003c\/style\u003e","published_at":"2021-03-26T13:49:03-04:00","created_at":"2021-03-26T13:43:08-04:00","vendor":"GreenTek Energy Systems","type":"LED Tube Light","tags":[],"price":560,"price_min":560,"price_max":560,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":39286427058219,"title":"Frosted \/ Cool White (5000K)","option1":"Frosted","option2":"Cool White (5000K)","option3":null,"sku":"GT-T8GBD418M-50-B","requires_shipping":true,"taxable":true,"featured_image":{"id":27986505203755,"product_id":6550243704875,"position":1,"created_at":"2021-03-26T13:43:10-04:00","updated_at":"2021-03-26T13:47:22-04:00","alt":"4ft 18W LED Linear Tube - Glass - Single End Bypass - Ballast Bypass - (UL Type B) - Green Light Depot","width":1700,"height":1700,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0931\/8152\/products\/glassTubesTypeB_cef12397-b946-4c45-b1e8-39e5ca3fa441.jpg?v=1616780842","variant_ids":[39286427058219,39286427090987,39286427123755,39286427156523]},"available":false,"name":"4ft 18W LED Linear Tube - Glass - Single\/Two End Bypass - Safety Thermal Fuses - Ballast Bypass - (UL Type B + DLC) *Buy By The Box Promo* - Frosted \/ Cool White (5000K)","public_title":"Frosted \/ Cool White (5000K)","options":["Frosted","Cool White (5000K)"],"price":560,"weight":277,"compare_at_price":null,"inventory_quantity":-10,"inventory_management":"shopify","inventory_policy":"deny","barcode":"101-100106","featured_media":{"alt":"4ft 18W LED Linear Tube - Glass - Single End Bypass - Ballast Bypass - (UL Type B) - Green Light Depot","id":20280955633707,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1700,"width":1700,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0931\/8152\/products\/glassTubesTypeB_cef12397-b946-4c45-b1e8-39e5ca3fa441.jpg?v=1616780842"}},"requires_selling_plan":false,"selling_plan_allocations":[]},{"id":39286427090987,"title":"Frosted \/ Natural White (4000K)","option1":"Frosted","option2":"Natural White (4000K)","option3":null,"sku":"GT-T8GBD418M-40-B","requires_shipping":true,"taxable":true,"featured_image":{"id":27986505203755,"product_id":6550243704875,"position":1,"created_at":"2021-03-26T13:43:10-04:00","updated_at":"2021-03-26T13:47:22-04:00","alt":"4ft 18W LED Linear Tube - Glass - Single End Bypass - Ballast Bypass - (UL Type B) - Green Light Depot","width":1700,"height":1700,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0931\/8152\/products\/glassTubesTypeB_cef12397-b946-4c45-b1e8-39e5ca3fa441.jpg?v=1616780842","variant_ids":[39286427058219,39286427090987,39286427123755,39286427156523]},"available":true,"name":"4ft 18W LED Linear Tube - Glass - Single\/Two End Bypass - Safety Thermal Fuses - Ballast Bypass - (UL Type B + DLC) *Buy By The Box Promo* - Frosted \/ Natural White (4000K)","public_title":"Frosted \/ Natural White (4000K)","options":["Frosted","Natural White (4000K)"],"price":560,"weight":277,"compare_at_price":null,"inventory_quantity":7066,"inventory_management":"shopify","inventory_policy":"deny","barcode":"101-100105","featured_media":{"alt":"4ft 18W LED Linear Tube - Glass - Single End Bypass - Ballast Bypass - (UL Type B) - Green Light Depot","id":20280955633707,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1700,"width":1700,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0931\/8152\/products\/glassTubesTypeB_cef12397-b946-4c45-b1e8-39e5ca3fa441.jpg?v=1616780842"}},"requires_selling_plan":false,"selling_plan_allocations":[]},{"id":39286427123755,"title":"Clear \/ Natural White (4000K)","option1":"Clear","option2":"Natural White (4000K)","option3":null,"sku":"GT-T8GBD418T-40-B","requires_shipping":true,"taxable":true,"featured_image":{"id":27986505203755,"product_id":6550243704875,"position":1,"created_at":"2021-03-26T13:43:10-04:00","updated_at":"2021-03-26T13:47:22-04:00","alt":"4ft 18W LED Linear Tube - Glass - Single End Bypass - Ballast Bypass - (UL Type B) - Green Light Depot","width":1700,"height":1700,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0931\/8152\/products\/glassTubesTypeB_cef12397-b946-4c45-b1e8-39e5ca3fa441.jpg?v=1616780842","variant_ids":[39286427058219,39286427090987,39286427123755,39286427156523]},"available":false,"name":"4ft 18W LED Linear Tube - Glass - Single\/Two End Bypass - Safety Thermal Fuses - Ballast Bypass - (UL Type B + DLC) *Buy By The Box Promo* - Clear \/ Natural White (4000K)","public_title":"Clear \/ Natural White (4000K)","options":["Clear","Natural White (4000K)"],"price":560,"weight":277,"compare_at_price":null,"inventory_quantity":-10,"inventory_management":"shopify","inventory_policy":"deny","barcode":"101-100107","featured_media":{"alt":"4ft 18W LED Linear Tube - Glass - Single End Bypass - Ballast Bypass - (UL Type B) - Green Light Depot","id":20280955633707,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1700,"width":1700,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0931\/8152\/products\/glassTubesTypeB_cef12397-b946-4c45-b1e8-39e5ca3fa441.jpg?v=1616780842"}},"requires_selling_plan":false,"selling_plan_allocations":[]},{"id":39286427156523,"title":"Clear \/ Cool White (5000K)","option1":"Clear","option2":"Cool White (5000K)","option3":null,"sku":"GT-T8GBD418T-50-B","requires_shipping":true,"taxable":true,"featured_image":{"id":27986505203755,"product_id":6550243704875,"position":1,"created_at":"2021-03-26T13:43:10-04:00","updated_at":"2021-03-26T13:47:22-04:00","alt":"4ft 18W LED Linear Tube - Glass - Single End Bypass - Ballast Bypass - (UL Type B) - Green Light Depot","width":1700,"height":1700,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0931\/8152\/products\/glassTubesTypeB_cef12397-b946-4c45-b1e8-39e5ca3fa441.jpg?v=1616780842","variant_ids":[39286427058219,39286427090987,39286427123755,39286427156523]},"available":true,"name":"4ft 18W LED Linear Tube - Glass - Single\/Two End Bypass - Safety Thermal Fuses - Ballast Bypass - (UL Type B + DLC) *Buy By The Box Promo* - Clear \/ Cool White (5000K)","public_title":"Clear \/ Cool White (5000K)","options":["Clear","Cool White (5000K)"],"price":560,"weight":277,"compare_at_price":null,"inventory_quantity":9737,"inventory_management":"shopify","inventory_policy":"deny","barcode":"101-100108","featured_media":{"alt":"4ft 18W LED Linear Tube - Glass - Single End Bypass - Ballast Bypass - (UL Type B) - Green Light Depot","id":20280955633707,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1700,"width":1700,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0931\/8152\/products\/glassTubesTypeB_cef12397-b946-4c45-b1e8-39e5ca3fa441.jpg?v=1616780842"}},"requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/0931\/8152\/products\/glassTubesTypeB_cef12397-b946-4c45-b1e8-39e5ca3fa441.jpg?v=1616780842","\/\/cdn.shopify.com\/s\/files\/1\/0931\/8152\/products\/glassTubes3_c67afaa0-10b5-40cc-957a-93853b400349.jpg?v=1616780842","\/\/cdn.shopify.com\/s\/files\/1\/0931\/8152\/products\/januaryTubesTypeB1_6abc0894-9e89-473e-869f-d15636401167.jpg?v=1616780842","\/\/cdn.shopify.com\/s\/files\/1\/0931\/8152\/products\/januaryTubesTypeB2_eb189339-66d0-4fc9-9c48-fcf5dcd004e3.jpg?v=1616780842","\/\/cdn.shopify.com\/s\/files\/1\/0931\/8152\/products\/glassTubesTypeB2_cfec5303-14df-4c62-9ff7-19881b8b91cb.jpg?v=1616780842","\/\/cdn.shopify.com\/s\/files\/1\/0931\/8152\/products\/glassTubesTypeB1_bb0bf622-a924-41f9-b9d2-13371dafb651.jpg?v=1616780842"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/0931\/8152\/products\/glassTubesTypeB_cef12397-b946-4c45-b1e8-39e5ca3fa441.jpg?v=1616780842","options":["Trim","Color"],"media":[{"alt":"4ft 18W LED Linear Tube - Glass - Single End Bypass - Ballast Bypass - (UL Type B) - Green Light Depot","id":20280955633707,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1700,"width":1700,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0931\/8152\/products\/glassTubesTypeB_cef12397-b946-4c45-b1e8-39e5ca3fa441.jpg?v=1616780842"},"aspect_ratio":1.0,"height":1700,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0931\/8152\/products\/glassTubesTypeB_cef12397-b946-4c45-b1e8-39e5ca3fa441.jpg?v=1616780842","width":1700},{"alt":"4ft 18W LED Linear Tube - Glass - Single End Bypass - Ballast Bypass - (UL Type B) - Green Light Depot","id":20280955666475,"position":2,"preview_image":{"aspect_ratio":1.0,"height":1700,"width":1700,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0931\/8152\/products\/glassTubes3_c67afaa0-10b5-40cc-957a-93853b400349.jpg?v=1616780842"},"aspect_ratio":1.0,"height":1700,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0931\/8152\/products\/glassTubes3_c67afaa0-10b5-40cc-957a-93853b400349.jpg?v=1616780842","width":1700},{"alt":"4ft 18W LED Linear Tube - Glass - Single End Bypass - Ballast Bypass - (UL Type B) - Green Light Depot","id":20280955699243,"position":3,"preview_image":{"aspect_ratio":1.0,"height":1700,"width":1700,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0931\/8152\/products\/januaryTubesTypeB1_6abc0894-9e89-473e-869f-d15636401167.jpg?v=1616780842"},"aspect_ratio":1.0,"height":1700,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0931\/8152\/products\/januaryTubesTypeB1_6abc0894-9e89-473e-869f-d15636401167.jpg?v=1616780842","width":1700},{"alt":"4ft 18W LED Linear Tube - Glass - Single End Bypass - Ballast Bypass - (UL Type B) - Green Light Depot","id":20280955732011,"position":4,"preview_image":{"aspect_ratio":1.0,"height":1700,"width":1700,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0931\/8152\/products\/januaryTubesTypeB2_eb189339-66d0-4fc9-9c48-fcf5dcd004e3.jpg?v=1616780842"},"aspect_ratio":1.0,"height":1700,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0931\/8152\/products\/januaryTubesTypeB2_eb189339-66d0-4fc9-9c48-fcf5dcd004e3.jpg?v=1616780842","width":1700},{"alt":"4ft 18W LED Linear Tube - Glass - Single End Bypass - Ballast Bypass - (UL Type B) - Green Light Depot","id":20280955764779,"position":5,"preview_image":{"aspect_ratio":1.0,"height":1700,"width":1700,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0931\/8152\/products\/glassTubesTypeB2_cfec5303-14df-4c62-9ff7-19881b8b91cb.jpg?v=1616780842"},"aspect_ratio":1.0,"height":1700,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0931\/8152\/products\/glassTubesTypeB2_cfec5303-14df-4c62-9ff7-19881b8b91cb.jpg?v=1616780842","width":1700},{"alt":"4ft 18W LED Linear Tube - Glass - Single End Bypass - Ballast Bypass - (UL Type B) - Green Light Depot","id":20280955797547,"position":6,"preview_image":{"aspect_ratio":1.0,"height":1700,"width":1700,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0931\/8152\/products\/glassTubesTypeB1_bb0bf622-a924-41f9-b9d2-13371dafb651.jpg?v=1616780842"},"aspect_ratio":1.0,"height":1700,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0931\/8152\/products\/glassTubesTypeB1_bb0bf622-a924-41f9-b9d2-13371dafb651.jpg?v=1616780842","width":1700}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cdiv class=\"page\" title=\"Page 2\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003e*MUST BUY IN MULTIPLES OF 25PC TO GET THE EXCLUSIVE OFFER* \u003c\/span\u003e\u003c\/p\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cspan\u003eNOTE: You must bypass the ballast. \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eExisting ballast can not be wired\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for this tube to work. Follow rewiring instructions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe LED T8 Glass Tube operates as a Bypass Tube which means it will bypass the existing ballast. These Glass T8 Tubes are energy efficient and provide energy savings of 70% or more. The T8 Tube produces over 100 Lumens per Watt. Additionally, the T8 Tubes are Eco-Friendly LED lights which do not emit UV or IR Radiation. Also, this lights provide great lighting without the occasional Flickering you may encounter with other tube lighting. Furthermore, the T8 Glass Tubes are Mercury Free and provide 50,000 hours or more of working bulb light. Our Glass Tubes are UL\/DLC Listed and come with a 3 year warranty.\u003c\/p\u003e\n\u003cp\u003eThis product is listed under DesignLights Consortium® (DLC) which does not only provide eligibility for rebates from most utility providers, but also promotes high-quality and energy-efficient lighting products through vigorous testing protocols.\u003c\/p\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003cp\u003eSKU: \u003cspan\u003e (4000K Milky) 101-100105,  (5000K Milky) 101-100106\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e (4000K Transparent) 101-100107, (5000K Transparent) 101-100108\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eQualification: UL\/DLC Listed\u003c\/p\u003e\n\u003cp\u003ePower: 18W\u003c\/p\u003e\n\u003cp\u003eReplaces up to: 32W T8 FL\u003c\/p\u003e\n\u003cp\u003eColor: 4000K, 5000K\u003c\/p\u003e\n\u003cp\u003eCRI: \u0026gt; 80\u003c\/p\u003e\n\u003cp\u003eInput Voltage: AC100-277V\u003c\/p\u003e\n\u003cp\u003ePower Factor: ≥ 0.90\u003c\/p\u003e\n\u003cp\u003eLifespan: 50,000 hours\u003c\/p\u003e\n\u003cp\u003eLumens: 2300LM\u003c\/p\u003e\n\u003cp\u003eLumens Per Watt (LPW): 100LPW\u003c\/p\u003e\n\u003cp\u003eBeam Angle (°): \u0026gt;220°\u003c\/p\u003e\n\u003cp\u003eWarranty: 5 years\u003c\/p\u003e\n\u003cp\u003eBase Type: G13\u003c\/p\u003e\n\u003cp\u003eMaterials: Glass\u003c\/p\u003e\n\u003cp\u003eIP Rating: IP20\u003c\/p\u003e\n\u003cp\u003eTrim: Clear, Frosted\u003c\/p\u003e\n\u003cp\u003eWiring: Single End \/ Two End\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0931\/8152\/files\/tempGrid_large.jpg?v=1500904352\" alt=\"\" width=\"578\" height=\"273\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eOperation and Maintenance Tips\u003cbr\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eStore and use the lamps as same as standard fluorescent lamps\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLamps should be kept free from contamination\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e Switch off mains supply before installing\/removing lamp\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eGood condition of the lamp-holder contacts is important to ensure proper operation of lamp\u003cbr\u003e \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e Use in fully enclosed fixtures may affect life performance\u003cbr\u003e \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e Not for use in emergency lighting circuits\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"\"\u003e\u003cstrong\u003e*When wiring single ended tubes, please ensure you are using an unshunted socket\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--\n.tftable {font-size:12px;color:#333333;width:100%;border-width: 1px;border-color: #a9a9a9;border-collapse: collapse;} .tftable th {font-size:12px;background-color:#b8b8b8;border-width: 1px;padding: 8px;border-style: solid;border-color: #a9a9a9;text-align:left;} .tftable tr {background-color:#ffffff;} .tftable td {font-size:12px;border-width: 1px;padding: 8px;border-style: solid;border-color: #a9a9a9;}\n--\u003e\u003c\/style\u003e"}

4ft 18W LED Linear Tube - Glass - Single/Two End Bypass - Safety Thermal Fuses - Ballast Bypass - (UL Type B + DLC) *Buy By The Box Promo*

Product Description
$ 5.60
Maximum quantity available reached.

Description

*MUST BUY IN MULTIPLES OF 25PC TO GET THE EXCLUSIVE OFFER* 

NOTE: You must bypass the ballast. Existing ballast can not be wired for this tube to work. Follow rewiring instructions.

The LED T8 Glass Tube operates as a Bypass Tube which means it will bypass the existing ballast. These Glass T8 Tubes are energy efficient and provide energy savings of 70% or more. The T8 Tube produces over 100 Lumens per Watt. Additionally, the T8 Tubes are Eco-Friendly LED lights which do not emit UV or IR Radiation. Also, this lights provide great lighting without the occasional Flickering you may encounter with other tube lighting. Furthermore, the T8 Glass Tubes are Mercury Free and provide 50,000 hours or more of working bulb light. Our Glass Tubes are UL/DLC Listed and come with a 3 year warranty.

This product is listed under DesignLights Consortium® (DLC) which does not only provide eligibility for rebates from most utility providers, but also promotes high-quality and energy-efficient lighting products through vigorous testing protocols.

Specifications

SKU:  (4000K Milky) 101-100105,  (5000K Milky) 101-100106

 (4000K Transparent) 101-100107, (5000K Transparent) 101-100108

Qualification: UL/DLC Listed

Power: 18W

Replaces up to: 32W T8 FL

Color: 4000K, 5000K

CRI: > 80

Input Voltage: AC100-277V

Power Factor: ≥ 0.90

Lifespan: 50,000 hours

Lumens: 2300LM

Lumens Per Watt (LPW): 100LPW

Beam Angle (°): >220°

Warranty: 5 years

Base Type: G13

Materials: Glass

IP Rating: IP20

Trim: Clear, Frosted

Wiring: Single End / Two End

Operation and Maintenance Tips

  • Store and use the lamps as same as standard fluorescent lamps
  • Lamps should be kept free from contamination
  • Switch off mains supply before installing/removing lamp
  • Good condition of the lamp-holder contacts is important to ensure proper operation of lamp
  • Use in fully enclosed fixtures may affect life performance
  • Not for use in emergency lighting circuits
*When wiring single ended tubes, please ensure you are using an unshunted socket

 